Optimization of injected radiotracer volume for flow rate measurement in closed conduits

Main Article Content

Miroslav M. Pavlović
Marijana R. Pantović Pavlović
Pavel Bartl
Jasmina Stevanović
Bojan Radak

Abstract

In chemical processes it is essential that the flow in the process is accurately defined. Fluid velocity measurements are important for fluid flow quality performance in flow systems. This study focuses on determination of the volumetric flow rate and its standard (relative) deviation for calibration of conventional flow meters by using a radiotracer approach. The measurements for flow meter calibration were performed at a pilot-scale flow rig using Technetium-99 m (99mTc) as a radiotracer in the form of pertechnetate ion (99mTcO4-). The measured data were analyzed, and precision of the experimental setup was investigated under two different approaches – IAEAs RTD software and sum approximation of raw data. For the first time, the variation of standard deviation of calculated flow rate with the injection volume and activity of the radiotracer was determined. Plug flow with axial dispersion was used to simulate the measured RTD curves and investigate the flow dynamics of the flowing water. The results of the study have shown the possibility of in situ calibration of flow meters with a relative error lower than 1 %. They also revealed a slight dependency of the precision of output results on the injection volume as well as similar results for manual and specialized RTD software data processing.

Downloads

Download data is not yet available.

Article Details

How to Cite
Pavlović, M. M., Pantović Pavlović, M. R., Bartl, P., Stevanović, J., & Radak, B. (2020). Optimization of injected radiotracer volume for flow rate measurement in closed conduits. HEMIJSKA INDUSTRIJA (Chemical Industry), 74(5), 305–312. https://doi.org/10.2298/HEMIND20050325P
Section
Chemical Engineering - Simulation and Optimization

References

Fogler HS. Elements of chemical reaction engineering. 2016.

Pant HJ, Yelgoankar VN. Radiotracer investigations in aniline production reactors. Appl Radiat Isot. 2002;57(3):319-325.

Othman N, Kamarudin SK. Radiotracer technology in mixing processes for industrial applications. Sci World J. 2014;2014.

Levenspiel O. Chemical Reaction Engineering. 3rd. New York: John Wiley & Sons Inc.; 1998.

van Gelder KB, Westerterp KR. Residence time distribution and hold-up in a cocurrent upflow packed bed reactor at elevated pressure. Chem Eng Technol. 1990;13(1):27-40.

Jafari M, Soltan Mohammadzadeh JS. Mixing time, homogenization energy and residence time distribution in a gas-induced contactor. Chem Eng Res Des. 2005;83(5 A):452-459.

Le Moullec Y, Potier O, Gentric C, Pierre Leclerc J. Flow field and residence time distribution simulation of a cross-flow gas-liquid wastewater treatment reactor using CFD. Chem Eng Sci. 2008;63(9):2436-2449.

Charlton JS. Radioisotope Techniques for Poblem-Solving in Industrial Process Plants. Glasgow: Leonard Hill; 1986.

Ben Abdelouahed H, Reguigui N, Abbes NE. Phosphate slurry RTD - Effect of the radiotracer choice. Appl Radiat Isot. 2016;115(2016):1-3.

Kasban H, Hamid A. Spectrum analysis of radiotracer residence time distribution for industrial and environmental applications. J Radioanal Nucl Chem. 2014;300(1):379-384.

IAEA. Radiotracer Residence Time Distribution Method for Industrial and Environmental Applications. Vienna, Austria; 2008.

Burkhardt T, Verstraete J, Galtier P, Kraume M. Residence time distributions with a radiotracer in a hydrotreating pilot plant: Upflow versus downflow operation. Chem Eng Sci. 2002;57(11):1859-1866.

Pant HJ, Sharma VK. Radiotracer investigation in an industrial-scale oxidizer. Appl Radiat Isot. 2015;99:146-149.

Pant HJ, Sharma VK, Vidya Kamudu M, Prakash SG, Krishanamoorthy S, Anandam G, Seshubabu Rao P, Ramani NVS, Singh G, Sonde RR. Investigation of flow behaviour of coal particles in a pilot-scale fluidized bed gasifier (FBG) using radiotracer technique. Appl Radiat Isot. 2009;67(9):1609-1615.

Pant HJ, Sharma VK, Singh G, Raman VK, Bornare J, Sonde RR. Radiotracer investigation in a rotary fluidized bioreactor. J Radioanal Nucl Chem. 2012;294(1):59-63.

Goswami S, Jagat H, Meenakshi P, Avinash S, Vijay C, Sharma K. Residence time distribution measurements in an industrial ‑ scale pulp digester using technetium ‑ 99m as radiotracer. J Radioanal Nucl Chem. 2019;(0123456789).

Goswami S, Pant HJ, Poswal D, Samantray JS, Asolekar SR. Investigation of flow dynamics of wastewater in a pilot-scale constructed wetland using radiotracer technique. Appl Radiat Isot. 2019;147(January):70-75.

Sarkar M, Sangal VK, Sharma VK, Samantray J, Bhunia H, Bajpai PK, Kumar A, Naithani AK, Pant HJ. Radiotracer investigation and modeling of an activated sludge system in a pulp and paper industry. Appl Radiat Isot. 2017;130(October):270-275.

Datta A, Kumar Gupta R, Goswami S, Kumar Sharma V, Bhunia H, Singh D, Jagat Pant H. Radiotracer investigation on the measurement of residence time distribution in an ethyl acetate reactor system with a large recycle ratio. Appl Radiat Isot. 2017;130(September):245-251.

Yelgaonkar VN, Jayakumar TK, Singh S, Sharma MK. Combination of sealed source and radiotracer technique to understand malfunctioning in a chemical plant. Appl Radiat Isot. 2009;67(7):1244-1247.

Kasban H, Zahran O, Arafa H, El-Kordy M, Elaraby SMS, Abd El-Samie FE. Laboratory experiments and modeling for industrial radiotracer applications. Appl Radiat Isot. 2010;68(6):1049-1056.

Thýn J, Žitný R. Radiotracer applications for the analysis of complex flow structure in industrial apparatuses. Nucl Instruments Methods Phys Res Sect B Beam Interact with Mater Atoms. 2004;213:339-347.

Thýn J, Žitný R. Problems of residence time distribution analysis with applications of radiotracers. J Radioanal Nucl Chem. 1996;205(2):225-233.

IAEA. Radiotracer Applications in Industry – A Guidebook. Vienna, Austria; 2004.

Hu QH, Technetium, in Atwood DA(Ed.), Radionuclides in the Environment, Wiley, New Work, 2010, p: 217-226.

Most read articles by the same author(s)